About PiVi

This author has not yet filled in any details.
So far PiVi has created 1503 blog entries.

Does asbestos-free fibre cement roofing provide thermal insulation?

A roof can be rain-tight and yet still fail to protect adequately against heat loss. These tasks belong to different parts of the building envelope. Fibre cement sheets are primarily a covering or cladding specified within a given system. Asbestos-free fibre cement does not replace a suitably selected thermal insulation. When choosing a material, it is worth separating the functions of the layers. That makes it easier to assess what a heated house, a workshop or an unheated warehouse needs. Materials differ in their ability to conduct heat, but their thickness matters too. A thin sheet may conduct heat less readily than metal and still have too low a thermal resistance to serve as proper building insulation.

By |2026-11-15T17:56:18+01:002023-05-12|Building guide|Comments Off on Does asbestos-free fibre cement roofing provide thermal insulation?

What do roof battens do beneath the covering?

Roof battens form the framework that supports the covering and mark where sheets are fixed, so before buying material it is worth agreeing with the contractor whether their spacing and cross-section match the geometry of the chosen profile and the expected loads. An even-looking finished frame is not enough — batten positions must suit the shape of the ribs, and for trapezoidal sheets the support method follows from the design and the tables for the specific profile. Also check that battens are not confused with counter-battens, which create a ventilation gap above the underlay.

By |2026-11-14T16:07:17+01:002023-05-11|Building guide|Comments Off on What do roof battens do beneath the covering?

Documenting Utherm Roof BM: thickness-dependent thermal conductivity

An unambiguous description of Utherm Roof BM should assign the lambda to the correct thickness range. Otherwise, the specification may promise a result that the selected board does not declare. The facings and the corresponding roof covering construction must be described just as precisely. Utherm Roof BM is a PIR board with different facings on both sides. One surface is finished with a bituminised glass fleece. The terms “polyurethane boards” and “polyurethane foam” are broader than the precise designation of the PIR product. In the description of the application of PIR boards, the two different surfaces of Utherm Roof BM must be clearly identified: bituminised and mineralised. The description of the function should make it possible to determine the orientation of the bituminised and mineralised side of Roof BM.

By |2026-11-16T00:53:41+01:002023-05-04|Building guide|Comments Off on Documenting Utherm Roof BM: thickness-dependent thermal conductivity

How to plan a safe route onto the roof

Before planning any access, decide whether the roof surface needs to be entered at all – many defects are visible from the ground, the loft or a safe platform. If entry is necessary, check the load-bearing capacity and condition of the structure, including areas weakened by corrosion or damp. The access route must lead safely from the ladder or roof hatch to the chimney, antenna or equipment, with support suited to the covering. Plan fall protection separately, along with the weather conditions under which work is permitted. These decisions will define the scope of the inspection and the choice of team.

By |2026-11-15T03:00:27+01:002023-05-01|Building guide|Comments Off on How to plan a safe route onto the roof

BauderPIR FA: coverage dimensions and construction specification data

For FA, a distinction must be made between the external dimension and the installation dimension. The first helps to describe the board, the second is used for planning the coverage. The specification should state which basis was used for the material quantity. This avoids an apparent conformity of the quotation that states the correct format but too small a number of boards. The BauderPIR FA specification should identify the function that the thermal insulation of a large, regular roof area is to perform. An element requiring an unambiguous description is the milled edge of the large-format board. The input data should include the area of actual coverage and the widths of the perimeter strips, not only the area intended for thermal insulation. The coordinating document remains the row plan based on the effective dimension of the boards.

By |2026-11-16T00:53:00+01:002023-04-30|Building guide|Comments Off on BauderPIR FA: coverage dimensions and construction specification data

BauderPIR FA: interpreting CS(10) when designing supports

When designing a support on a roof with FA, CS must be distinguished from long-term load conditions. It is worth specifying the contact area and the load-distributing layer. The figure in kilopascals alone does not describe a finished detail. The required documentation should also allow verification of the protection of the covering and the load transfer path. The BauderPIR FA specification should identify the function that the roof is to perform with equipment resting on the layers above the insulation. One element requiring an unambiguous description is the bearing area of the foot of the roof-mounted equipment. The input data should include the force transmitted by the support and its actual contact area, not merely the area intended for thermal insulation. The coordinating document remains the support drawing showing the load transfer path and the protection of the covering.

By |2026-11-16T00:53:06+01:002023-04-27|Building guide|Comments Off on BauderPIR FA: interpreting CS(10) when designing supports

How to plan internal insulation for a tenement building?

Internal insulation of a tenement building requires identifying the wall construction and its moisture levels. A thin PIR board can help limit the loss of space and improve comfort. However, not every historic wall build-up will tolerate such a change well. The impact of rain, the condition of the floors and the ability of the building elements to dry out must be checked. Particular attention is needed for beams embedded in the wall, reveals and junctions between rooms. In a tenement building, the wall may contain several types of brick, old repairs and remnants of previous finishes. The properties of the wall need not be uniform. Its behaviour is also affected by moisture from the ground, leaking gutters and driving rain. Adding insulation from the inside changes the thermal conditions of this build-up.

By |2026-11-14T09:55:57+01:002023-04-19|Building guide|Comments Off on How to plan internal insulation for a tenement building?

Ventilated fibre cement roofs: maintaining an uninterrupted air path

Roof ventilation only works when air can enter, flow through and escape to the outside. The space beneath the covering alone is not enough. Fibre cement sheets can be part of such a system, but its effectiveness depends on the whole assembly. Asbestos-free fibre cement does not remove moisture indefinitely. Airflow helps create the conditions for drying, so it must be planned as carefully as the details that protect against rain. Ventilating rooms and ventilating the layer beneath the covering are different tasks. In an outbuilding they may be connected, but they should not be equated. An insulated roof may have a separate cavity separated from the interior.

By |2026-11-15T17:56:20+01:002023-04-19|Building guide|Comments Off on Ventilated fibre cement roofs: maintaining an uninterrupted air path

Selecting a roofer and agreeing how the work will be carried out

First check whether the roofer has experience with roofs of similar geometry and covering, not just simple slopes. When choosing a contractor, compare full scopes of work, establish responsibility for measurements and purchases, and agree how concealed layers will be documented. Ask about safety organisation and acceptance stages. Remember that material quality is not the same as workmanship quality, and an offer made without assessing the structure's condition may cover only basic covering.

By |2026-11-15T03:01:34+01:002023-04-18|Building guide|Comments Off on Selecting a roofer and agreeing how the work will be carried out

How to insulate a wall from the inside with a PIR board with aluminium facing?

A PIR board with aluminium facing allows the thickness of internal insulation to be reduced. Success depends on dry masonry, a proven layer build-up and airtight joints. The foil on the board surface alone does not protect the whole wall. Reveals, ceilings, corners and service penetrations require the most attention. The finishing method and fire protection must also be established before installation. This solution is considered when the façade cannot be changed or there is not enough space on the outside of the wall. Thinner insulation helps preserve the room's floor area. However, it does not remove all the limitations of this method. After internal insulation, the masonry becomes cooler and its ability to dry out may change.

By |2026-11-14T09:55:24+01:002023-04-10|Building guide|Comments Off on How to insulate a wall from the inside with a PIR board with aluminium facing?
Back to top