Building handbook
The Izoprofil.eu handbook covers roofing, wall cladding and insulation, from reading specifications to preparing an order. Find guidance on sandwich panels, PIR boards, trapezoidal sheets and metal roof tiles. Understand overall sheet width and effective cover width, compare insulation options and plan installation details. The articles also cover renovation, material storage and costs that are easy to overlook. Worked examples explain the calculation method. Check the design and product documentation before making the final selection. Once you have identified the material, prepare the dimensions, quantity and delivery location for a quote.
Fence picket spacing: balancing an open appearance and privacy
The gaps between pickets are just as important as the profiles themselves. They reveal glimpses of the garden, change how the colour is perceived and affect how well the property is screened. Metal fence pickets set closely together can look like a solid surface. The same elements spaced more openly create a more open rhythm. However, there is no single gap that suits every house. The choice should follow from where the fence will be viewed, the need for privacy and the actual layout of the structure. It is worth checking several variants before ordering material. Ask what should be visible through the fence. At the entrance, contact with a visitor may matter. By the terrace, limiting visibility may be more important. Along a side boundary, a calm view of greenery is sometimes needed. These needs do not always lead to identical spacing across the whole property. Sections can be varied while keeping a common profile and colour.
What do the properties of termPIR MAX 19 AL actually tell you?
The name MAX 19 draws attention to the thermal properties. However, the documentation for termPIR MAX 19 AL also contains mechanical data and reaction-to-fire conditions. Product selection requires reading them together, without assuming an automatic advantage in every category. termPIR MAX 19 AL is a board made of rigid PIR foam, protected on both sides with a gas-tight laminate of aluminium, paper and polyethylene. Its primary distinguishing feature is its level of thermal conduction. In the specification for the application described as PIR boards, clearly indicate the place where little space remains for insulation under the existing flashing. The cross-section at the existing flashing must be checked before using the advantage of the low lambda value, and the adopted variant must be clearly marked in the documentation.
Specifying Utherm Floor LE: data needed for floor construction
The Utherm Floor LE specification should state more than thickness and lambda. The design needs loads, the load-distributing layer and the rules for forming the edges. Data for another UNILIN board does not replace the documents specific to the product intended for the floor. Utherm Floor LE is a PIR board intended for floors. It has gas-tight laminate on both sides with a printed grid. The terms “polyurethane boards” and “polyurethane foam” are broader than the precise designation of the PIR product. In the description of the application of PIR boards, the limited floor level at the doors in the solution with Utherm Floor LE must be clearly indicated. The description of the function should allow the height of Floor LE, the substrate, the services and the finished covering to be added together.
Does asbestos-free fibre cement roofing provide thermal insulation?
A roof can be rain-tight and yet still fail to protect adequately against heat loss. These tasks belong to different parts of the building envelope. Fibre cement sheets are primarily a covering or cladding specified within a given system. Asbestos-free fibre cement does not replace a suitably selected thermal insulation. When choosing a material, it is worth separating the functions of the layers. That makes it easier to assess what a heated house, a workshop or an unheated warehouse needs. Materials differ in their ability to conduct heat, but their thickness matters too. A thin sheet may conduct heat less readily than metal and still have too low a thermal resistance to serve as proper building insulation.
What do roof battens do beneath the covering?
Roof battens form the framework that supports the covering and mark where sheets are fixed, so before buying material it is worth agreeing with the contractor whether their spacing and cross-section match the geometry of the chosen profile and the expected loads. An even-looking finished frame is not enough — batten positions must suit the shape of the ribs, and for trapezoidal sheets the support method follows from the design and the tables for the specific profile. Also check that battens are not confused with counter-battens, which create a ventilation gap above the underlay.
Documenting Utherm Roof BM: thickness-dependent thermal conductivity
An unambiguous description of Utherm Roof BM should assign the lambda to the correct thickness range. Otherwise, the specification may promise a result that the selected board does not declare. The facings and the corresponding roof covering construction must be described just as precisely. Utherm Roof BM is a PIR board with different facings on both sides. One surface is finished with a bituminised glass fleece. The terms “polyurethane boards” and “polyurethane foam” are broader than the precise designation of the PIR product. In the description of the application of PIR boards, the two different surfaces of Utherm Roof BM must be clearly identified: bituminised and mineralised. The description of the function should make it possible to determine the orientation of the bituminised and mineralised side of Roof BM.