BauderPIR FA-TE in terrace and roof specifications

For FA-TE, the market documentation describes various details of the geometry. The designer should specify the variant and require confirmation of the edge in the delivery. A straight edge from one document should not be combined with the effective dimension from another. An unambiguous description is particularly important when accounting for small areas and offcuts. The BauderPIR FA-TE specification should identify the function that the thermal insulation of the terrace above a room is to perform. An element requiring an unambiguous description is the threshold of the terrace door and the nearby drain. The input data should include the distance between the substrate and the permissible level of the surfacing, and not only the area intended for thermal insulation. The coordinating document remains the terrace section at the door with the marked levels.

By |2026-11-16T00:53:01+01:002022-04-09|Building guide|Comments Off on BauderPIR FA-TE in terrace and roof specifications

Metal fence pickets seen from the street and the garden

A fence has a street-facing side and a house-facing side. The first more often appears in photos, the second accompanies everyday use of the property. Metal fence pickets are worth choosing with both perspectives in mind. From the garden side, crossbars, connections and the rear surfaces of the profile appear. They do not have to look identical to the front, but they should form an orderly whole. Keeping to one colour principle and a similar finish for all connections helps. The structure is then legible, even if it remains visible. A good design does not end with the colour of the most representative side. Check the view from windows, the terrace and the most frequently used path. At these points the fence may occupy a large part of the field of view. Note which crossbars will run at eye level. It is not about removing necessary supports. It is about consciously planning their colour and their relationship to the rhythm of the pickets. The internal view also deserves a design.

By |2026-11-15T17:54:35+01:002022-03-17|Building guide|Comments Off on Metal fence pickets seen from the street and the garden

Bending prepainted sheet without spoiling the shape or finish of the flashing

Non-standard flashings are made from flat sheet, but once bent they must satisfy several requirements at the same time. They must fit the building, keep the correct surface, and be installable. Matching leg lengths alone is not enough. The material, the actual shape of the corners and the bending sequence all matter. It is worth agreeing these points before production, especially when the flashing will be visible along a long stretch of façade. Coated sheets are not a single variant with identical forming capabilities. The type of substrate, the thickness and the arrangement of the protective layers all matter. The shape should match the properties of the specific sheet. The material should not be changed arbitrarily once a demanding cross-section has been approved.

By |2026-11-15T03:03:54+01:002022-03-14|Building guide|Comments Off on Bending prepainted sheet without spoiling the shape or finish of the flashing

Specifying Thermano Deck: properties that depend on board thickness

Thermano Deck does not have a single set of parameters for all thicknesses. Both lambda and the declared mechanical properties change. The specification should therefore refer to a specific board, and not to the most favourable figures from different rows of the table. Thermano Deck has a PIR core and a multilayer gas-tight facing containing aluminium on both sides. The product is intended, among other things, for classic flat roofs. In the specification for the application described as PIR boards, clearly indicate the large area of a flat roof based on trapezoidal sheet metal and finished with parapets. Thermano Deck must be selected together with the vapour control layer, the substrate and the method of executing the waterproofing, and the adopted variant must be clearly marked in the documentation.

By |2026-11-16T00:52:09+01:002022-02-18|Building guide|Comments Off on Specifying Thermano Deck: properties that depend on board thickness

Designing internal insulation with termPIR AL GK

Internal thermal insulation changes the temperature and moisture distribution in the wall. A design using termPIR AL GK should therefore include an analysis of the entire building component and its junctions. The gypsum plasterboard layer does not remove the need for continuous sealing and for selecting the right fixing method. termPIR AL GK is a composite. The insulating part made of PIR foam has a gas-tight facing on both sides, and on the interior side there is a 12.5 mm thick gypsum plasterboard. In the application specification for what are described as PIR boards, clearly identify the interior-side wall, where a single board is to provide both insulation and a substrate for the finish. The masonry beneath termPIR AL GK must be surveyed before it is enclosed under the insulation and the new gypsum surface, and the adopted variant must be clearly marked in the documentation.

By |2026-11-16T00:51:58+01:002022-01-23|Building guide|Comments Off on Designing internal insulation with termPIR AL GK

Designing with Eurothane G: insulation RD and plasterboard thickness

The design with Eurothane G should clearly state which parameters relate to the PIR and which relate to the entire composite. The plasterboard has its own thickness and properties. Mixing up these data can overstate the assessed insulation performance or make it difficult to check the dimensions after completion of the works. Recticel Eurothane G consists of a PIR board faced on both sides with a gas-tight facing and with 12.5 mm plasterboard. It is intended for suitable internal insulation applications. In the specification of the application described as PIR boards, clearly indicate the internal wall facing that bonds Eurothane G PIR to the 12.5 mm plasterboard. The wall beneath Eurothane G must be prepared in accordance with its condition and the requirements of the new construction, and the adopted variant must be clearly identified in the documentation.

By |2026-11-16T00:52:32+01:002022-01-17|Building guide|Comments Off on Designing with Eurothane G: insulation RD and plasterboard thickness

Specifying Recticel Eurofloor: CS versus permissible loading

The value of 120 kPa in the Eurofloor data describes a specific material test result. It should not be entered directly as the permissible service load. Floor design also requires an assessment of long-term and point loads and of how they are distributed. Recticel Eurofloor has a rigid PIR foam core and a multi-layer gas-tight foil with a printed grid on both sides. The manufacturer intends it for thermal insulation of floors, including those with underfloor heating. In the application specification described as PIR boards, clearly indicate a floor with a heating installation located in the layers above the thermal insulation. Eurofloor must be placed in the correct floor cross-section together with the planned heating installation, and the adopted variant must be clearly marked in the documentation.

By |2026-11-16T00:52:26+01:002022-01-12|Building guide|Comments Off on Specifying Recticel Eurofloor: CS versus permissible loading

Vapour control layers beneath fibre cement roofing: when are they needed?

The need for a vapour control layer is not decided by the name of the covering alone. Temperature, indoor humidity and the layer build-up of the roof are more important. Fibre cement sheets can cover both an open canopy and a heated attic. In each case, water vapour behaves differently. Asbestos-free fibre cement does not replace a layer that controls its flow. The choice of such a solution must be linked to airtightness and the ability of the assembly to dry out. Simplified guidance usually refers to vapour diffusion through materials. In a real building, the flow of moist air through gaps is also significant. A leaky joint at a wall or duct can supply moisture to cool layers.

By |2026-11-15T17:56:34+01:002021-12-14|Building guide|Comments Off on Vapour control layers beneath fibre cement roofing: when are they needed?

Designing with Utherm Sarking LE Plus: edges, membrane and details

The description of Utherm Sarking LE Plus should separate the product data from the calculation of the counter-batten fixing. The large format and the edge profile do not determine the screw spacing. The project also needs membrane details so that the scope of supply matches the intended execution. Utherm Sarking LE Plus belongs to the PIR boards for pitched roofs. On both sides it has a multi-layer gas-tight laminate. The terms “polyurethane boards” and “polyurethane foam” are broader than the precise designation of the PIR product. In the description of use for PIR boards, the difference between Utherm Sarking LE and the LE Plus variant with the additional membrane must be stated unambiguously. The description of function should make it possible to establish the full name of the Sarking variant before additional membranes are selected.

By |2026-11-16T00:53:38+01:002021-11-05|Building guide|Comments Off on Designing with Utherm Sarking LE Plus: edges, membrane and details

Energy renovation across several buildings: setting priorities and comparing results

A thermal modernisation programme covering several buildings needs a common assessment method and separate solutions for each property. A school, a residential building and a commercial unit differ in operating hours, the condition of the building envelope and how the services perform. On Izoprofil.eu we describe how to prepare the order of renovations: gathering data, identifying urgent defects, selecting the scope and checking the results once the works are complete. PIR boards can be one of the insulation materials, especially where the geometry of the existing detail limits the space available for layers. Their suitability, however, is determined by the requirements of the specific building element. A shared schedule of the investment helps compare the needs of the buildings without attributing the same savings to all of them. The reference point should be energy consumption together with a description of comfort and how the building is used.

By |2026-11-15T17:55:10+01:002021-10-07|Building guide|Comments Off on Energy renovation across several buildings: setting priorities and comparing results