Specifying PIR boards in construction drawings and material schedules
PIR boards in a design require a description that leads to an unambiguous order and acceptance. The material abbreviation and the thickness alone are usually not enough. Characteristics relevant to the given building element are needed. A well-prepared specification also makes it possible to assess a substitute without guessing the designer's intention. In practice, it is worth separating three questions. What is the core made of? What parameters does the finished board have? How should it be installed? Only the answers to the whole set allow the solution to be assessed. Insulation with polyurethane is not a single technology with identical installation on every surface. In the name of the material item, separate the type of core from the form of the product. Polyurethane foam is a broader term than a factory-made PIR board with a specified facing.