About PiVi

This author has not yet filled in any details.
So far PiVi has created 1503 blog entries.

Planning a sandwich panel garage and estimating the build cost

A garage from insulated panels can be built efficiently if you plan the foundation, structure, door and cladding in advance. The price of the panels alone is not enough to determine the budget. The way the garage is used also matters. A cold storage space for a car requires a different solution from a heated workshop. First establish the dimensions and requirements, then order the material. Note the car dimensions, the space needed at the door and the space for shelving. The external width of the garage is not the clear drive-through width. Some of the space will be taken up by columns, door tracks and wall layers. Also check the height of the open door and any drive unit. These centimetres are difficult to recover once the roof is installed.

By |2026-11-14T12:15:03+01:002024-04-07|Building guide|Comments Off on Planning a sandwich panel garage and estimating the build cost

Can you walk on insulated roof panels?

Can you walk on a sandwich roof panel? The answer depends on the specific assembly, not on panel thickness alone. Before stepping onto it, check the manufacturer's documentation, the support spacing, the fixing pattern and the technical condition of the roof. Snow load capacity does not automatically permit any point load, so it is worth establishing what service conditions are envisaged for the given roof. A completed, fixed roof is treated differently from a loose panel or a stored pack. Where equipment is serviced regularly, it is worth providing suitable routes and walkways.

By |2026-11-14T16:06:08+01:002024-04-06|Building guide|Comments Off on Can you walk on insulated roof panels?

What makes insulated roof panels easier to install?

Installing a roof sandwich panel is made easier above all by checking the supports and details in advance — this step prevents the greatest number of problems. It is worth verifying that the structure matches the design, along with the spacing and straightness of the supports and the condition of their protection, because unevenness hinders fitting and can deform the facings during fixing. The factory-made product itself combines an outer steel facing, an insulating core and an inner facing, and its geometry and properties are strictly defined. Permissible spans should be read for the specific panel variant and load conditions, not inferred from insulation thickness alone.

By |2026-11-14T16:09:30+01:002024-04-04|Building guide|Comments Off on What makes insulated roof panels easier to install?

How to choose a PIR board under render for an aerated concrete wall?

For an aerated concrete wall, choose a PIR board intended for the given façade system. A good lambda value alone is not enough. What matters is the adhesion of the facing, the fixing into the substrate and the correct execution of the reinforced layer and render. The insulation thickness follows from the wall parameters and the thermal target. There is no single value suitable for all blocks. Aerated concrete comes in various grades and thicknesses. Its thermal and mechanical properties depend on the specific product. When selecting insulation, do not assume the parameters of the warmest block if it is not known what the wall was built from. Check the documentation or carry out the necessary inspection.

By |2026-11-14T09:55:42+01:002024-03-22|Building guide|Comments Off on How to choose a PIR board under render for an aerated concrete wall?

Air humidity and cold roof surfaces: why roofing alone is not enough

The building owner often looks for the cause of moisture solely in the covering. Meanwhile, the conditions under the roof can change once a wet load is introduced, the heating is switched on or the gates are closed. Corrugated fibre cement sheets react to their surroundings just like the other materials of the building envelope. Asbestos-free fibre cement does not regulate the interior humidity on its own. To limit water on the cold roof slope, its sources and the way air is exchanged must be identified. A percentage humidity reading is not straightforward information about the amount of water in the entire room. A change in temperature also changes this indicator. That is why two measurements taken at different times require context. Merely heating the air can lower its relative humidity without removing moisture from the building.

By |2026-11-16T00:50:05+01:002024-03-15|Building guide|Comments Off on Air humidity and cold roof surfaces: why roofing alone is not enough

Above-rafter PIR insulation: designing details and fixings

The specification for an above-rafter (PIR) roof should go beyond the insulation thickness. PIR boards must be tied to the substrate, the protective layers and the load transfer. The design should also clearly show the junction between the roof slopes and the façade, and the terminations at openings. PIR boards laid above the rafters form a layer that also covers the timber structural elements. This allows their contribution to heat flow through the roof to be reduced. The calculation must take into account the actual sequence of layers through the construction. A continuous layer above the rafters has a different geometry from the bay infill alone. The thermal calculation must reproduce the actual non-uniformity of the roof.

By |2026-11-16T00:55:45+01:002024-03-12|Building guide|Comments Off on Above-rafter PIR insulation: designing details and fixings

Preparing a metal roof for repainting

Painting a sheet-metal roof makes sense only when the metal is sound and the old coatings and causes of damage have been identified. This guide gives owners and contractors the criteria for judging whether a covering is suitable for renovation and the steps needed to prepare it. It is worth checking the degree of corrosion, coating adhesion and the condition of fixings, as well as the underside of the sheets, where rust will not disappear after painting. Removing the source of recurring damage before new paint protects the prepared substrate is equally decisive.

By |2026-11-14T19:20:59+01:002024-03-09|Building guide|Comments Off on Preparing a metal roof for repainting

How do you calculate the required thickness of PIR board for a wall?

The required PIR thickness can be preliminarily calculated from the required thermal resistance of the wall. However, you need to know the existing layers and the parameters of the selected board. A calculator based only on the type of masonry gives too little information. The final selection also takes into account fixings, thermal bridges, moisture and the method of finishing. The calculation result must be translated into an available product suitable for the application. Record all wall layers, their thicknesses and thermal properties. Include existing insulation and voids, if they actually occur. For an old house, the documentation may need to be verified on site. Do not assume that every brick or aerated concrete wall has the same resistance.

By |2026-11-14T09:55:59+01:002024-03-05|Building guide|Comments Off on How do you calculate the required thickness of PIR board for a wall?

Choosing a roof covering for a garage

The choice of garage roof covering depends primarily on how the interior will be used, not on the roof area alone. Check whether the garage will be heated, whether it will serve as a workshop, and what pitch and support spacing the design specifies. A wet car brings moisture into an unheated garage. Plan how to keep rain out, drain it away and ventilate the space so that moisture does not collect under the sheets. A sandwich panel combines layers into one element, but its thickness and fire resistance must be selected. Compare complete systems, not just the sheets.

By |2026-11-14T19:21:43+01:002024-03-05|Building guide|Comments Off on Choosing a roof covering for a garage

How do you assess heat and moisture transfer through a building element?

A reliable result starts with a correct description of the wall or roof. You need to know all the layers, their thicknesses and properties, as well as the conditions on both sides of the building envelope. The low lambda of PIR helps to reduce the insulation thickness. However, it is not enough to assess the entire system. The thermal calculation must be supplemented by checking moisture, thermal bridges and the airtightness of joints. Record the layer build-up from the interior to the exterior. Include plaster, masonry, existing insulation, air cavity and finish. Do not omit old insulation just because it will not be replaced. During renovation, its condition and actual thickness may require an inspection opening. A photo of the façade does not provide this data.

By |2026-11-14T09:55:23+01:002024-03-01|Building guide|Comments Off on How do you assess heat and moisture transfer through a building element?