Building handbook
The Izoprofil.eu handbook covers roofing, wall cladding and insulation, from reading specifications to preparing an order. Find guidance on sandwich panels, PIR boards, trapezoidal sheets and metal roof tiles. Understand overall sheet width and effective cover width, compare insulation options and plan installation details. The articles also cover renovation, material storage and costs that are easy to overlook. Worked examples explain the calculation method. Check the design and product documentation before making the final selection. Once you have identified the material, prepare the dimensions, quantity and delivery location for a quote.
Calculating the U-value of an EPS-insulated wall: a worked example
The U-value of a wall can be estimated by adding up the resistances of its layers and the surface heat transfer resistances. For a homogeneous layer, the formula R = d/λ is used, and then U = 1/R total. The calculation requires the thickness in metres and the correct material data. Only afterwards are corrections, fixings and junctions with other building components assessed. Lambda describes heat conduction through a material. It is given in W/(m·K). A lower value means a greater resistance for the same insulation thickness. R describes the resistance of a specific layer and has the unit m²K/W. U relates to the entire building component. Its unit is W/(m²·K). Therefore, the number 0.032 cannot be compared with the number 0.18 without checking which parameter they belong to.
Is the lowest lambda value enough to select foundation insulation?
At the foundation, a low lambda value is important, but it is not enough to choose EPS. The board must match the water conditions, the loads and the installation location. Insulation on a vertical wall has a different task from the material under a loaded slab. Data on water absorption, compression and long-term performance are needed. Waterproofing remains a separate layer. The ground, the water level and the method of rainwater drainage must be identified. Contact with a damp substrate differs from periodic or constant exposure to water. The design should specify the conditions to which the insulation will be exposed. A material should not be chosen solely on the basis that a neighbouring house was insulated with a similar board.
Specifying ETICS requirements without prescribing a product name
ETICS can be described by the required properties and conditions of use without specifying a particular trade name. However, the principle of a complete, documented system must be retained. The lambda value of the EPS alone plus a list of random adhesives and renders is not enough. A good description covers the substrate, the fixing, the layers, the performance requirements and the rules for accepting substitutes. The description should specify the type of wall, its condition and the scope of preparatory work. A new wall requires a different assessment from old render with localised debonding. Information on height, geometry and wind loads is needed. Without these, the fixing cannot be reliably determined. Specifying a universal spacing of anchors does not replace the assessment of a specific façade.
Using environmental product declarations to compare EPS
An EPD environmental declaration helps to compare the environmental impact of insulation, but it requires careful reading. What counts is the reference unit, the scope of the life-cycle stages and the actual function of the material. A kilogram or a cubic metre of two boards does not necessarily give the same thermal insulation performance. An EPD also does not replace the technical data needed to use EPS in a building. A type III EPD contains structured data on the environmental impact of the product. It is produced according to specific rules and is subject to verification. It shows indicators and the assumptions of the life-cycle analysis. It is not a simple good-or-bad assessment. The mere fact of having the document does not mean that the product has the smallest impact in every category and in every application.
BauderPIR T: coordinating falls and thermal performance in roof design
The BauderPIR T specification requires a geometry drawing and a schedule of tapered boards. A statement of 2% fall alone does not define the starting height, the route of the drainage channels or the position of the outlets. The thermal calculation must correspond to the actual distribution of thicknesses. The documentation should make it possible to reproduce this arrangement on site. The BauderPIR T specification should identify the function that the roof with uncoated tapered boards is to perform. One element requiring an unambiguous description is the drainage channel directing water towards the outlet. The input data should include the substrate levels and the route of the water-collecting lines, not only the area intended for thermal insulation. The coordinating document remains the falls drawing with the direction in which the thickness increases. It should be recorded who confirms the feasibility of the task: to achieve the required drainage path and a correct thermal section.
XPS thermal conductivity: declared values and design values
Lambda appears in almost every thermal insulation offer. In the case of XPS, it usually refers to the declared thermal conductivity, designated λD. A lower value means a lower ability of the material to conduct heat under specified reference conditions. However, extruded polystyrene should be assessed together with the thickness and the conditions of application. A single figure from the headline of an offer does not yet answer the question of how a finished floor, wall or roof will perform. The declared lambda describes a property of the product determined according to the rules applying to a given group of materials. It allows XPS to be compared on a common basis. It should be read from the documentation for the specific variant, not from a general description of all of the manufacturer's boards.