About PiVi

This author has not yet filled in any details.
So far PiVi has created 1403 blog entries.

Protecting sheet metal roofing against rust at edges and fixings

Protecting a metal roof from corrosion depends above all on matching the coating to the conditions around and inside the building. It is worth checking whether the chosen variant is permitted for the given environment, what its application limits are and what maintenance it requires. Neither the colour alone nor a declared warranty determines how effective the protection will be. The sections that follow cover transport, cutting, drainage and upkeep, which influence the durability of the covering just as much.

By |2026-11-15T03:00:31+01:002026-02-24|Building guide|Comments Off on Protecting sheet metal roofing against rust at edges and fixings

Trapezoidal steel sheet weights: calculating the mass of an order

The weight of trapezoidal sheet is determined mainly by thickness, material and profile geometry, not by the height of the trapezoid alone. Before comparing offers, check whether the stated value refers to a gross, effective or running metre, as this is the most common source of error. For an order, the total weight of all sheets together with flashings and packaging matters, while for roof design the other layers and loads also count. Choosing thinner sheet may reduce stiffness and permissible span, so leave the decision on the section to the designer.

By |2026-11-14T19:21:19+01:002026-02-22|Building guide|Comments Off on Trapezoidal steel sheet weights: calculating the mass of an order

Designing the connection between a steel building and its foundations

The connection between a steel hall and its foundation requires calculation of the entire node. Anchors, base plate, concrete, grout and the method of transferring forces are selected. A chemical anchor is one of the available solutions, but it does not suit every hall automatically. The bar diameter and hole depth should not be chosen on the basis of the building's mass or general advice. The entire connection system is checked. The base transfers vertical and horizontal forces as well as moments resulting from the structure's behaviour. Wind can cause part of the connection to be lifted, even though the entire hall is heavy. Loads depend on the frame layout, bracing and location conditions. Therefore the number of anchors does not simply follow from the size of the base plate.

By |2026-11-14T12:16:13+01:002026-02-21|Building guide|Comments Off on Designing the connection between a steel building and its foundations

Single- or double-module roofing sheets: what difference does the format make?

The number of modules in a metal roofing tile determines how many repeating pattern rows an individual sheet contains, not the number of corrugations across its width. Before choosing a format, compare the effective coverage area rather than the external dimensions, and analyse the cutting layout for the specific roof geometry. Also check whether offcuts can be reused and how installation costs compare. It is worth comparing two cutting plans, the number of pieces and the required flashings. The final choice depends on the roof layout and work organisation, so leave detailed technical decisions to the designer.

By |2026-11-14T16:08:24+01:002026-02-16|Building guide|Comments Off on Single- or double-module roofing sheets: what difference does the format make?

What does an eaves flashing do at the gutter?

The over-gutter flashing is the trim that takes water from the roof slope and directs it into the gutter, but it works effectively only when matched to the specific eaves detail. Before ordering, check whether its profile suits the gutter height, the roof covering overhang and the membrane layout. Its cooperation with ventilation is also crucial, as is distinguishing it from the under-gutter flashing, which serves a different purpose. The article discusses these relationships and the consequences of incorrect selection and installation.

By |2026-11-14T22:54:49+01:002026-02-15|Building guide|Comments Off on What does an eaves flashing do at the gutter?

Where is T35 trapezoidal steel sheet suitable and what does its load-bearing capacity depend on?

T35 is a profile chosen for roofs and cladding requiring a greater profile height than T18. However, the suitability of the sheet is determined by the entire cross-section, thickness and steel grade. The symbol alone does not specify the permissible support spacing. Before purchase, the coverage width, profile side and installation conditions must also be established. This allows products to be compared without confusing the dimensions and load-bearing capacities of different variants. Sheet with this profile can be found on garages, agricultural buildings, workshops and halls. It is also sometimes used on façades. Its pronounced ribs give the surface a technical character. From a design perspective, however, transferring loads to the purlins or battens is more important than appearance.

By |2026-11-14T09:50:45+01:002026-02-13|Building guide|Comments Off on Where is T35 trapezoidal steel sheet suitable and what does its load-bearing capacity depend on?

Keeping roofing costs down on a house, garage or open shelter

The cheapest roof does not always follow from the lowest price per metre of sheet metal – the final bill is also shaped by waste, the substrate, flashings, insulation and installation. Before comparing quotes, record the roof pitch, support spacing and how the room will be used, and check whether the roof will be seen close up. A simple carport may need only a lighter covering, whereas above a heated garage you must account for heat, air tightness and moisture. Look for savings in matching the material to the building and in sensible sheet division, not in the profile number alone.

By |2026-11-14T22:54:24+01:002026-02-12|Building guide|Comments Off on Keeping roofing costs down on a house, garage or open shelter

What thickness of PIR insulated wall panel should I choose?

The thickness of a PIR wall panel follows from the target thermal performance, the construction and the way the building is used. You do not choose it for a heated hall the same way as for an unheated warehouse. You need to compare the U-values of specific panels, the type of joint, the facings and the permissible spans. Details at the plinth and around openings also matter. The number of millimetres alone does not give a full answer. Establish the temperature and the heating regime. In a workshop used every day, heat loss through the walls matters differently than in a seasonal facility. An unheated warehouse may also need insulation, for example to limit temperature fluctuations. This does not mean, however, that the panel alone will provide the expected temperature there.

By |2026-11-14T12:17:37+01:002026-02-09|Building guide|Comments Off on What thickness of PIR insulated wall panel should I choose?

Planning safe snow removal from a roof

The key is assessing the structure, not the snow depth alone. A building owner should check whether the roof's design conditions are known and whether snow lies evenly. Fresh powder and wet, compacted snow of the same depth can mean different loads, so a handbook figure in centimetres is not enough. It is also worth establishing how to secure the area under the eaves and protect the metal coating during work. The scope of work for a crew should follow from documentation and observations made from a safe place, not from generic recommendations.

By |2026-11-14T19:19:34+01:002026-02-06|Building guide|Comments Off on Planning safe snow removal from a roof

Tile-effect or trapezoidal steel sheets: which suits the building?

The choice between modular metal tile and trapezoidal sheeting depends mainly on the roof geometry and the desired pattern of lines across the slope. Metal tile mimics the fine rhythm of small roof elements, while trapezoidal profile creates pronounced longitudinal ribs. Before comparing costs, check whether a given profile suits the pitch, the support spacing and the number of valleys and dormers. Also consider the effective cover width and how sheets are cut, as these affect waste. Only then compare coatings, insulation and acoustics.

By |2026-11-14T22:55:27+01:002026-02-05|Building guide|Comments Off on Tile-effect or trapezoidal steel sheets: which suits the building?
Back to top