The Izoprofil.eu handbook covers roofing, wall cladding and insulation, from reading specifications to preparing an order. Find guidance on sandwich panels, PIR boards, trapezoidal sheets and metal roof tiles. Understand overall sheet width and effective cover width, compare insulation options and plan installation details. The articles also cover renovation, material storage and costs that are easy to overlook. Worked examples explain the calculation method. Check the design and product documentation before making the final selection. Once you have identified the material, prepare the dimensions, quantity and delivery location for a quote.

Selecting soffit sheets and estimating the cost of finishing the eaves

Choosing roofing sheet for a soffit starts with establishing whether the eaves require an air inlet, as this determines the layout of panels and openings. Also check the geometry of the structure, the exposed face of the sheet and how it will be fixed to the supporting frame. The cost of the finish covers more than the sheet area: trims, flashings, fixings, ventilation components and work at corners all count. Drawing out the strip layout helps limit waste and shows whether offcuts can be reused. Remember that a soffit will not repair a leaking eaves – water ingress must be resolved before installation.

Tile-effect metal sheets or bitumen shingles: which suits your roof?

The choice between metal roofing tiles and bituminous shingles depends on the roof pitch, geometry and condition of the structure, not on the price of the outer layer alone. Before deciding, check whether the chosen material falls within the permitted slope range and whether the existing substrate needs preparation or replacement. Also compare the requirements for ventilation, detail flashings and subsequent maintenance. Remember that comfort and cost are determined by the entire layer build-up, not just the visible surface of the covering.

How to choose a repair for a leaking metal roof

First establish whether water is actually penetrating the covering or is the result of condensation of water vapour beneath the metal sheet. That distinction determines the repair method, since tape and sealant will not fix every cause. Check the condition of the washers, the geometry of the laps, the flashings at the chimney and wall, and any corrosion of the sheets. Also assess the roof pitch and whether drainage is unobstructed. With sandwich panels, the core and the joint may matter. Only after locating the water path and assessing the substrate can a durable or temporary solution be chosen.

Box gutters and half-round gutters: how do they differ?

The choice between square and half-round gutters depends not only on aesthetics but, above all, on whether a given system will drain a specific roof slope effectively. It is worth checking the cross-section, the number and position of outlets, the fall, and the fit to the eaves and façade. Shape alone does not guarantee greater capacity – flow depends on dimensions and the completeness of the system. When comparing, consider materials, installation method, service access and the cost of the whole set, not just the gutter price.

Thermano GK-A and GK-H2: composite thickness and thermal resistance in design

In the description of Thermano GK, a distinction must be made between the PIR foam and the finished composite board. The total thickness includes the gypsum plasterboard facing. Using the lambda of the core alone for the entire product can therefore lead to an overly optimistic calculation result. Thermano GK-A and Thermano GK-H2 combine a PIR core in gas-tight facings with a 12.5 mm thick gypsum plasterboard. The GK-A variant has a white facing for typical dry rooms. In the application specification described as PIR boards, clearly indicate the choice between the white GK-A facing and the green GK-H2 facing in a room with a defined function. The GK-A or GK-H2 variant must be assigned to the function and conditions of use of the room, and the selected variant must be clearly marked in the documentation.

What should you check before buying 100 mm second-grade wall panels?

To check a 100 mm second-grade sandwich wall panel, first establish whether the specific batch meets the project requirements, not just the thickness. Inspect the locks along their full length, the condition of the facings and core, and the documents confirming the properties. Assess whether the defects are purely visual or affect the panel's construction. Compare the full specification, because PIR and mineral wool variants may have different insulation, weight and fire classification. Leave the suitability decision to the designer.

Back to top