BauderPIR M/MF: selecting properties from current documents

PIR insulation

At a glance

For M/MF, the lambda value must be assigned to a specific thickness. For example, 100 mm should be calculated using the applicable range, not the value for the aluminium-faced board. It is worth recording the mineral facing and the M or MF edge separately, so that a substitute product can be assessed against the full set of relevant characteristics. The BauderPIR M/MF specification should identify the function the roof with the mineral-faced PIR board is to fulfil. The area of the fleece under the waterproofing layer is an element that requires an unambiguous description. The input data should include the thickness of the insulation ordered and the condition of the substrate under the covering, not only the area to be insulated. The coordinating document remains the set of documents for the specific M or MF thickness and the connection to the covering.

BauderPIR board with a mineral facing and exposed cream-coloured PIR core

Input data for the specification

It must be recorded who confirms that the task can be carried out: establish the correct lambda and a compatible connection with the covering. In this respect, the person responsible should be the specialist who approves the compatibility of the insulation with the covering, in accordance with the division of design work.

The correct product and the scope of its data

BauderPIR M/MF is recognised by the construction of the board: a PIR core with mineral fleece on both sides, family format 1200 × 600 mm, whereby M and MF differ in the shape of the edge. The Polish data sheet for M assigns λD 0.026 W/(m·K) to the range from 80 mm to below 120 mm, so 0.022 should not be treated as a constant for the whole family. The documentation states at least 120 kPa in the compression test and fire reaction E. The field of application is defined by the roof with PIR board in a mineral facing; the properties of the complete board comprise the PIR core and the facings, and installation consists of laying the factory-made boards in a defined layer arrangement.

What the presented calculation covers

For BauderPIR M/MF with a thickness of 100 mm, a lambda of 0.026 W/(m·K) is assumed for the example calculation. The approximately 3.85 m²K/W obtained from 0.10/λ is the result of a calculation, not a declared RD; read the declared data from the documents for the selected variant. The connection detail with the covering must moreover identify the fleece on both surfaces and the M or MF edge. This enables the installer to reproduce both the thermal layer and the correct connection of materials.

When checking an alternative to BauderPIR M/MF, compare separately the thickness range with the lambda assigned to it and the compatibility of the mineral fleece with the waterproofing. Reading only the family name does not allow both characteristics to be approved. Record the document designation, the selected variant and the result of the check of the connection with the covering; such a protocol will make it possible to return to the assumptions if the supplier proposes a different board.

Conditions for assessing the variant

In the project, it is possible to compare the action described as the behaviour of the designed facing and the selection of the required thickness with the solution that consists in changing the entire confirmed assembly after re-comparison. The criterion should follow from the need to establish the correct lambda and a compatible connection with the covering. For BauderPIR M/MF, retaining a single figure from the data sheet does not mean that the entire cross-section is equivalent. The requirements must also take into account the profile — plain in M or milled in MF. Recalculation of the board with mineral facing using the lambda of the aluminium variant must be excluded, because this changes the meaning of the recorded parameter. The decision should be presented by the specialist who approves the compatibility of the insulation with the covering, together with the scope of changes for adjacent materials. The adopted variant must be linked to the schedule: a list of parameters covering thickness, facing and edge.

Description of the execution of the important connection

The drawing should unambiguously indicate the area of the fleece beneath the waterproofing layer. In the case of BauderPIR M/MF, the surface of the material formed by the matt mineral fleece must also be described. The preparation must provide a level substrate beneath the board with undamaged fleece. The required inspection point occurs before the stage described as waterproofing covering compatible with the mineral facing. The basis for acceptance is the description of the fleece on both surfaces and of the correct edge profile, assigned to the drawing and the place of execution. Such a description limits discretionary decisions by the team at a point that will not be visible later.

Delivery and acceptance documents

The delivery of BauderPIR M/MF should be assignable to a single specification item. This item is expanded by the list of parameters covering thickness, facing and edge; each described feature should have a reference to the project. A description of the fleece on both surfaces and of the correct edge profile is needed, allowing the variant and the manner of its use to be confirmed. If conditions change, the condition of compatibility of the mineral facing with the adopted system must be reconsidered. The update should be agreed by the specialist who approves the compatibility of the insulation with the covering before the next layer conceals the discrepancy. In this way, the polyurethane insulation is linked to the executed scope, which is the roof with PIR board in mineral facing.

A record that can be checked later

Close the acceptance of BauderPIR M/MF with a compilation of the delivery data and the cross-section drawing. It should show which thickness was adopted, from which document its lambda was read and how the connection of the fleece with the covering was confirmed. If the detail at the edge differs from the main field, mark it separately. Assess every subsequent change of variant according to the same criteria; the name PIR alone does not justify retaining the previous calculations and method of bonding.

7 branches. Materials closer to your project.

Izoprofil.eu map of seven branches offering sandwich panels, PIR boards and sheet metal