What does the water vapour diffusion resistance factor μ mean for EPS?

Expanded polystyrene and thermal insulation

At a glance

The μ factor states what resistance a material offers to water vapour diffusion compared with air. It does not describe thermal insulation performance or water absorption. For the entire layer, the thickness also matters, which is taken into account by the parameter sd = μ × d. EPS data must be read for the specific grade and used in the analysis of the whole building component. μ is a dimensionless diffusion resistance factor. It relates the resistance of the material to the resistance of an air layer of the same thickness under comparable conditions. A higher value means greater hindrance to vapour flow by diffusion. It does not mean greater tightness against liquid water or resistance to flooding. These properties are checked with other parameters and methods.

White EPS behind a transparent pane with water droplets, detail for discussing vapour diffusion

What does the μ coefficient compare?

The Greek symbols μ and λ should not be confused. Lambda describes heat conduction, while μ relates to water vapour. Two boards with a similar lambda do not necessarily have identical diffusion resistance. Likewise, a higher μ does not prove better or worse thermal insulation. The selection should separate these functions instead of reducing all properties to a single term, breathable.

Why is the sd parameter also needed?

The resistance of an actual layer depends not only on the material but also on its thickness. For a homogeneous layer, sd = μ × d, where d is given in metres. The result, sd, is also in metres and denotes the air thickness equivalent in diffusion terms. A board of greater thickness has a greater sd for the same μ. The material coefficient alone therefore does not describe the complete assembly.

Let us assume μ = 40 and an EPS thickness of 15 cm. We obtain sd = 40 × 0.15 = 6 m. When the thickness increases to 20 cm, sd will be 8 m. This is an example calculation for an assumed μ. It does not mean that every EPS board has a value of 40. Likewise, the sd of a thin membrane cannot be compared with the μ of polystyrene alone, because these are quantities with different units and meanings.

Where can data for expanded polystyrene be obtained?

The property may be stated in a declaration, technical data sheet or documentation used for design. For some boards a range is encountered, for example μ from 20 to 40. Such an entry must be applied in accordance with the rules of analysis. One should not independently choose the value that gives the most favourable result. Depending on the assembly, a different limit of the range may be the unfavourable one.

The document should relate to the exact variant of the material. One should not transfer μ from XPS to EPS or from an uncoated board to a laminated product. The facing can significantly change the resistance of the whole product. The current version of the data is also important. If the property has not been specified in a given document, the absence of an entry does not mean zero resistance to vapour.

How does μ affect the assessment of condensation?

Vapour diffusion depends on the conditions on both sides of the building component and on the resistance of the successive layers. At the same time, the temperature distribution results from their thermal properties. A condensation analysis combines these issues. The risk cannot be determined merely by reading off the μ of the EPS. The masonry, renders, membranes, covering and the conditions inside and outside must all be taken into account.

Adding EPS on the outside changes the temperatures within the existing wall and its vapour diffusion resistance. The result depends on the complete assembly. The simple rule that each successive layer must have a lower μ does not replace a calculation. Thickness, i.e. sd, and the ability to dry out also matter. With damp masonry or an unusual design, a more detailed analysis than the standard simple model may be needed.

Diffusion is not ventilation or draughtiness

Vapour flow through a material differs from air movement through a gap. The latter can transport moisture by another route and does not follow directly from the μ of the board. EPS laid tight-jointed does not automatically create an airtight air layer. The junctions at windows, floors and services must be resolved. A higher vapour diffusion resistance will not remedy an open gap.

The wall also does not replace the designed air exchange in the room. Ventilation must remove excess moisture and ensure suitable conditions of use. It should not be restricted on the basis that a vapour-permeable material was used. On the other hand, a good ventilation system does not remove the need for a correct design of the layers. Both issues must be checked separately and coordinated.

How can the parameter be used when selecting EPS?

μ matters when it is needed for a moisture analysis. It does not constitute a stand-alone ranking of polystyrene quality. Lambda, thickness, intended use and mechanical properties also come into the choice. In the foundation, parameters relating to contact with water are also important. A material with a favourable μ may be unsuitable in a given location for a completely different reason, for example because of insufficient compressive strength.

The manufacturers of EPS include, among others, Arsanit, Paneltech, Genderka and Swisspor. Their specific boards should be compared on the basis of documents and project requirements. In the comparison, it is worth separating λ, μ, sd and water absorption. Such an order protects against confusing the flow of heat, vapour, air and water, which in a building require different solutions.

7 branches. Materials closer to your project.

Izoprofil.eu map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]

Check prices and availability: +48 500 409 109

Free quote

Materials for your project