XPS creep: why compressive strength alone is not enough

XPS insulation

At a glance

An XPS board can carry a load for many years. This happens under a floor finish, beneath terrace layers or under a suitably designed foundation. For these applications, short-term compressive resistance is not the only thing that matters. Extruded polystyrene must also be assessed for creep, that is, the change in deformation under a sustained load. This parameter helps to select the material for conditions where stable support and a limited change in layer thickness matter. The material may deform at the moment of loading and then change shape as time passes. This later part of the behaviour is the essence of creep. XPS comes in variants with different properties, so the data for the specific product are needed for calculations.

Yellow XPS boards lying next to each other, with an open joint between the edges

What happens after a load is applied

One should not assume that every rigid material retains a perfectly constant thickness under a load that acts for years.

Extruded polystyrene makes it possible to match the insulation to a wide range of loads, provided the available documentation corresponds to the application. The creep value is not a defect in itself. It is information that allows the behaviour of the XPS layer to be predicted and the movement of the entire system to be limited. The better the service conditions are defined, the easier it is to select the material without oversizing or adopting an unjustified margin.

What short-term compression describes

The designation CS(10/Y) refers to the compressive stress at a specified deformation, or to the compressive strength determined in accordance with the test method. It is useful when comparing XPS, but it does not on its own define its long-term behaviour. The value associated with ten percent deformation is not a permissible pressure under a finished floor. It is the result of a material test, not a complete design decision.

A simple example illustrates the scale of the difference well. Ten percent of a thickness of 100 mm is 10 mm. Such a large compression of the layer under the floor would be a significant change. Extruded polystyrene is therefore selected taking into account much more narrowly defined service conditions. XPS with a higher CS value may be needed, but the other data and the way the load is distributed in the building element must still be checked.

How to understand the CC designation

In documents one may encounter an example notation CC(2/1.5/50)130. It combines requirements relating to total deformation, creep, the assessment period and stress. In this example the figures refer respectively to the levels of 2% and 1.5%, the period of 50 years and the stress of 130 kPa. This is an example of a notation method, not a parameter assigned to all XPS boards available on the market.

Extruded polystyrene should be assessed on the basis of the full designation. The final number alone, without the criterion of deformation and time, can lead to an incorrect comparison. The 50-year period in the XPS designation does not mean that every sample was tested for that length of time. The result follows from the proper procedure and the assessment of behaviour over time. It is also not in itself a guarantee of service life for an identical period.

The deformation of the layer also depends on the thickness

The same percentage of deformation means a different change in dimension for thin and thick insulation. Two per cent of 100 mm is 2 mm, and of 200 mm it is 4 mm. These are arithmetic examples that show why the thickness of XPS is structurally significant. Thermal insulation should therefore not be increased without checking whether the entire system still meets the requirements for permissible displacements.

Extruded polystyrene under a slab or base works together with the layers above it. The distribution of forces, local loads and evenness of support are important. XPS selected solely on the basis of the average pressure over the entire surface may not be suitable for the zone under a shelving unit foot. The designer also takes into account the calculation rules and the required coefficients. The material declaration is a necessary input datum, not a finished design.

What to do when the document states NPD

The designation NPD means that no declared performance characteristic is available for a given item. It is not equivalent to zero creep, nor is it proof of unsuitability for all applications. For XPS under a specific load, however, the necessary basis for calculation may then be lacking. The relevant data for the planned use must be obtained, or a product with documentation corresponding to the requirements must be selected.

It is worth checking whether the data sheet and the declaration of performance refer to the same variant and thickness. XPS may come in several versions with similar names. Transferring a parameter from one to another requires confirmation, not assumption. It is beneficial to record the exact long-term performance requirement in the specification. This allows the offer and the delivery to be checked before installation begins.

Selection based on service conditions

XPS is produced by, among others, Austrotherm, Synthos and Ravago. Their products should be compared on the basis of specific declarations, not a general opinion about hardness. The colloquial word styrodur does not describe creep. It is worth giving the designer a load plan, the planned equipment and the expected function of the building element. This allows the mechanical advantages of the material to be used in a way that corresponds to the actual task.

Extruded polystyrene can provide effective insulation under load when its deformations remain in accordance with the design. In doing so, the XPS must be laid on a suitable substrate and the layer arrangement must be maintained. Creep documentation helps to predict long-term performance, and precise execution allows the conditions on site to be brought closer to the assumptions made. Both elements are needed for a rigid board to be a good component of the entire building element.

7 branches. Materials closer to your project.

Izoprofil.eu map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]

Check prices and availability: +48 500 409 109

Free quote