IKO enertherm ALU TAP: specifying falls and tapered board thicknesses
PIR insulation
The ALU TAP documentation should assign each slope to a marked field. If the outlet is changed, both the drawing and the parts list must be updated. It is also worth defining how the levels are to be checked and accepted before waterproofing. Merely confirming that the PIR tapered board has been delivered does not prove that the layout is correct. The IKO enertherm ALU TAP specification should identify the function that a roof with aluminium-faced tapered boards of different slopes is to perform. One element requiring an unambiguous description is the junction between fields with a different drainage direction. The input data should include the height difference between the ends of the taper and the length in the direction of fall, not only the area to be insulated.

In this article
Input data for the specification
The coordinating document remains the drainage field plan with slopes and heights marked. It must be recorded who confirms that the task can be carried out: arrange the appropriate wedges so that they direct water in accordance with the plan. In this respect, the person responsible should be the designer of the drainage and of the tapered insulation system, in accordance with the division of design work.
The product concerned and the scope of its data
IKO enertherm ALU TAP is available as a tapered board with a PIR core and aluminium laminate on both sides, in a 1200 × 1200 mm format and with straight edges. The available slopes are 0.83%, 1.25% and 1.67%. The declared lambda is 0.022 W/(m·K), the compressive strength at least 175 kPa, and the reaction to fire E. When selecting parameters, the name PIR alone is not enough: the specification must link the choice of wedges to the drainage plan and to the thermal calculation, which takes account of the variable thickness. The properties are attributed to the complete board, i.e. the core together with the facings, and not to the core alone. Installation means laying factory-made boards in a defined layer arrangement, which is why the description in the specification should identify the function of the roof with aluminium-faced tapered boards of different slopes, and not just the material itself.
What the presented calculation covers
Example geometry: a 1.00 m section with a constant slope of 1.25% gives a height difference between the ends of approximately 12.5 mm. The slope value comes from the IKO enertherm ALU TAP documentation, but the example does not define a complete field or the starting height. The level at the outlet depends additionally on the substrate and the underlying layers, so the coordination of drawings must cover the detail of the junction of fields with a different drainage direction. The result should not be treated as the thermal resistance of the roof. To check equivalence and execution, a drainage field plan with slopes and heights marked and with the actual course of all sections is needed.
For IKO enertherm ALU TAP, the distinction must be maintained between the product data and the result of the entire solution. The analysis uses the characteristic: the choice among slopes of 0.83%, 1.25% and 1.67%. The assessment must take account of the limitation: the order of the elements between the outlet and the edge. Before approving the variant, the designation of the element must be compared with its actual position in the project and the result recorded in the documentation. Reproducing the assumptions is made possible by the drainage field plan with slopes and heights marked. As a result, a later comparison with another offer does not omit the element described as the junction of fields with a different drainage direction.
Conditions for assessing the variant
In the design, it is possible to compare the action described as separating the supply by fields and types of wedges with the solution of changing the layout after rechecking the position of the outlets. The criterion should follow from the need to arrange the correct wedges so that they direct water in accordance with the plan. For IKO enertherm ALU TAP, retaining a single figure from the data sheet does not mean that the entire cross-section is equivalent. The requirements must also take into account the simple contact of adjacent wedges in accordance with the drawing. Interchanging elements of similar thickness and different slope must be excluded, because this changes the meaning of the recorded parameter. The decision should be presented by the designer of the drainage and of the tapered insulation system, together with the scope of changes for adjacent materials. The adopted variant must be linked to the schedule: a list of ALU TAP wedges with their slopes separated.
Description of the execution of the important connection
The drawing should clearly indicate the junction of fields with a different drainage direction. In the case of IKO enertherm ALU TAP, the surface of the material formed by the aluminium facing of the square tapered board should also be described. The preparation must provide a substrate that maintains the designed levels of the tapered fields. The required point of inspection occurs before the stage described as the covering laid on the accepted tapered field. The basis for acceptance is the list of wedge labels and the results of the slope-direction measurement, assigned to the drawing and the place of execution. Such a description limits discretionary decisions by the crew at a point that will not be visible later.
Delivery and acceptance documents
The delivery of IKO enertherm ALU TAP should be assignable to a single specification item. This item is expanded by the list of ALU TAP wedges with their slopes separated; every described characteristic should have a reference to the design. A list of wedge labels and the results of the slope-direction measurement is needed, allowing the variant and the manner of its use to be confirmed. If conditions change, the order of elements between the outlet and the edge must be reconsidered. The update should be agreed by the designer of the drainage and of the tapered insulation system before the next layer hides the discrepancy. Polyurethane insulation is thus linked to the executed scope, namely the roof built using aluminium-faced wedges with the specified gradients.
A record that can be checked later
The final description of IKO enertherm ALU TAP should allow the adopted decision to be reproduced without guessing its purpose. In this case, the purpose can be defined as selecting and positioning the wedges to carry water along the routes shown in the design. The description should be accompanied by a drainage field plan indicating slopes and heights. Separately, it is worth indicating the junction of fields with a different drainage direction where its solution differs from the main field. The record should cover the entire required scope. When proposing a substitute, the element’s designation must be compared again with its actual position in the design, instead of basing the assessment solely on the name PIR. Polyurethane boards are then compared according to verifiable characteristics and their effects on the specific cross-section.