Specifying Eurothane Silver: product data, thickness and edges

PIR insulation

At a glance

The description of Eurothane Silver should refer to the current documentation and a specific thickness. In the latest data sheet, the parameters differ between the thin 20 mm variant and the other boards. Omitting this distinction makes it difficult to verify an offer and a delivery. Recticel Eurothane Silver is a PIR board with a multi-layer gas-tight foil on both sides and a printed grid. The current data sheet specifies it for flat roofs in a classic configuration. In the specification of use described as PIR boards, clearly indicate the classic flat roof, for which mechanical fastening, bonding or ballast is considered. Eurothane Silver must be assigned to a specific mechanically fastened, bonded or ballasted system, and the chosen variant must be clearly marked in the documentation.

Recticel Eurothane Silver PIR board with visible core and actual product facing

Scope of data in the specification

Recording the name alone is not enough, because the board’s wide range of applications does not mean that components from different systems can be combined at will. The functional assumptions are intended to allow one agreed configuration to be selected before the insulation and the waterproofing layer are ordered. In the design documentation, include the substrate, the waterproofing variant and the documentation of how the roof layers are joined, together with a reference to the relevant cross-section.

Lambda, thickness and thermal resistance

In the calculation of the building element, use the declared lambda of 0.022 W/(m·K) for Eurothane Silver, valid for the range 20–200 mm; the board thickness results from these calculations, not from the product description alone.

When comparing polyurethane boards in calculations, describe the Eurothane Silver layer selected according to lambda 0.022 W/(m·K) and the required roof height separately. The influence of fasteners and terminations must be checked in the calculation of the entire roof with Eurothane Silver, so that each value can be linked to the correct version of the calculation. The parameter must remain linked to the declared range, since the R of an equal section of board does not include a correction for each fastener passing through the insulation. Verification of the design should allow the material parameter to be compared with the geometry and the fixing method of the actual roof. Keep in the calculation the thickness of the main field, the number and type of fasteners and the detail of the thermal insulation perimeter, so that a later material change can be traced.

Interpretation of mechanical and fire properties

The Eurothane Silver data sheet of September 2026 distinguishes CS120 for a thickness of 20 mm and CS150 from 30 mm. Reaction-to-fire class F applies to boards from 30 mm; for 20 mm it remains undetermined. In the specification, do not fill in the missing class with data from the thicker variant.

In the table of mechanical and fire requirements, distinguish the difference between CS120 for 20 mm and CS150 from 30 mm given in the current data sheet. After changing the Silver thickness, the mechanical data and the scope of the fire declaration must be read again, so that the product document does not replace the required assessment of use. Evidence for one case cannot be extended arbitrarily, because B-s2,d0 refers to the specified application on sheet metal, and not to any free-standing board. The product and application documents should allow the distinction between the properties of Eurothane Silver and the assessment of the complete roof system to be maintained. When approving the material, compare the relevant row of the parameter table and the classification conditions corresponding to the designed structure with the actual configuration of the building element.

For Eurothane Silver, data should not be carried over from one thickness to all items in the schedule. The 20 mm variant has separate information on format, CS and the reaction-to-fire declaration. The material table should preserve these distinctions. The end-use classification must be assigned to the specific assembly on the substrate. This reduces the risk of a similar commercial description being treated as full confirmation of compliance.

Moisture through the full cross-section

Select the vapour control layer and the waterproofing to suit the conditions of the building in which Eurothane Silver is laid. The gas-tight surface of the board does not seal the gaps across the whole roof, so on its own it is not sufficient.

The analysis of moisture conditions should cover the junction between the roof field and the parapet wall and any installation routed through the roof. The water shield and the vapour control layer must be connected at the parapet and at the service penetrations in accordance with the thermal and moisture conditions adopted for the building element. The description “polyurethane foam” does not conclude the analysis, because the gas-tight foil on Eurothane Silver leaves all the gaps between components to be resolved. The adopted layers and their connections must allow the sealing layers to be joined where different materials meet, without reducing the task to taping over the boards. In the specification, explain the arrangement of the vapour control layer, the upstands of the covering and the method of sealing the specific penetration, as well as the limits of responsibility of the individual layers.

Support and details on the drawing

The choice of Eurothane Silver format depends on the thickness: 20 mm is available exclusively in the 600 × 1200 mm format, whereas 2400 × 1200 mm boards are available in the remaining thicknesses. On the construction drawing, indicate the roof exposure area, the spacing of obstacles and the resulting number of boards in both formats, then assign the correct dimension to each zone. Describe the board edge as square or as the ordered rebate and link it to the laying direction and the method of covering. Carry these determinations through to the specification and the acceptance, so that the dimension of the supplied board and its edge can be checked on site.

In the construction drawing, describe precisely the choice of the 600 × 1200 or 2400 × 1200 mm format and the ordering of the specific edge. The Silver format and edge must be matched to the delivery thickness and the number of obstructions on the roof slope, and the method of verification must be shown on the construction drawing. This cannot be left solely to the installation decision, since the 20 mm variant appears in the data sheet only in the smaller format. The adopted geometry should allow the insulation to be set out according to the variant actually available for the adopted thickness. The designed polyurethane insulation requires specifying how to check the dimension of the delivered board, the straight edge or the ordered rebate, and the coverage area at acceptance.

Purchase conditions and checking the substitute product

In the specification and the request for quotation, state for Eurothane Silver the thickness, the edge and the covering system in which the board is to perform. The silver surface with the grid print is not a sufficient criterion for equivalence, because visually similar PIR boards may have a different range of application or different mechanical properties. Assess the substitute by its facing and the intended purpose of the assembly, not only by lambda. Record the comparison criteria in the report, indicating the full name, thickness, side profile and the scope of works for closing the roof.

When checking the item “polyurethane insulation” in the bill of quantities, analyse offers covering similarly looking silver boards but different roof systems. The conformity of the Silver substitute must be assessed by facing and application in addition to thermal parameters, and the agreed criteria must remain clear during the assessment of the substitute. Conformity of a single feature is not enough when a similar grid print does not prove identical suitability for the adopted covering. The material procedure should allow technical equivalence to be verified before comparing amounts per square metre of insulation. Enter the full name Eurothane Silver, the thickness, the side profile and the scope of works for closing the roof in the conformity report, so that the decision is not based solely on the commercial description.

7 branches. Materials closer to your project.

Izoprofil.eu map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]

Check prices and availability: +48 500 409 109

Free quote