Documenting Utherm Roof BM: thickness-dependent thermal conductivity

PIR insulation

At a glance

An unambiguous description of Utherm Roof BM should assign the lambda to the correct thickness range. Otherwise, the specification may promise a result that the selected board does not declare. The facings and the corresponding roof covering construction must be described just as precisely. Utherm Roof BM is a PIR board with different facings on both sides. One surface is finished with a bituminised glass fleece. The terms “polyurethane boards” and “polyurethane foam” are broader than the precise designation of the PIR product. In the description of the application of PIR boards, the two different surfaces of Utherm Roof BM must be clearly identified: bituminised and mineralised. The description of the function should make it possible to determine the orientation of the bituminised and mineralised side of Roof BM.

Utherm Roof BM – construction of the board and its facing

PIR Roof BM boards with two different facings

A shortened material item is not enough, because the vapour-permeable fleece must not be equated with an aluminium laminate. The functional criteria are intended to allow each face of the board to be assigned the correct contact with the adjacent layer. In the documentation, include a description of the facings and the technology for making the connection with the covering, and clearly indicate the place of application.

Lambda of Roof BM dependent on thickness

The lambda value of Roof BM must be assigned to a specific thickness, because the technical data sheet gives three ranges: 30–70 mm – 0.027 W/(m·K), 80 and 100 mm – 0.026, 120–150 mm – 0.024. The calculation schedule should therefore show the transition from 0.026 for 100 mm to 0.024 W/(m·K) for 120 mm, and not a single lambda for the whole family. Such an entry in the specification allows a replacement to be checked later according to the same assumptions.

In the calculations, the parameters of each thickness variant of Roof BM under consideration must be read separately. The data must remain within their range, since the quotient d/λ must not use the lambda of another thickness range of this board. Verification of the solution should allow the thermal variants to be compared without transferring the best result to the whole family. Retain the declared R_D of 3.80 for 100 mm and 5.00 m²K/W for 120 mm, so that a later replacement can be checked according to the same assumptions.

Polyurethane insulation with straight edges

The 1200 × 600 mm format and straight edges are data that must go into the construction design as a board layout, and not only into the product description. Before starting the works, the orientation of the surfaces and the requirements of the waterproofing system must be confirmed; the drawing must show the arrangement of the straight edges of Roof BM in the 1200 × 600 mm format so that the execution is in accordance with the adopted solution.

The construction drawing should help plan the offset joints and cut-offs of Roof BM at roof elements. It is not worth leaving this to the crew at the last minute, given that the straight edge has no factory-made overlap that could be matched in the adjacent row. The adopted geometry is intended to maintain continuous contact between the boards and to finish the layer correctly at the edges. For acceptance of the polyurethane insulation, specify the joint layout, the support of the edge elements and the method of forming the penetrations. Also define the inspection to be carried out before covering.

Contact with the covering and the sequence of works

The method of connecting the covering to the bituminised surface of Roof BM is part of the analysis of the building envelope conditions, not merely an installation step. The design and specification should therefore state the requirements for adhesion, cleanliness and dryness of the surface, as well as verification of the fixing in the central, edge and corner zones of the roof, so that the coordination of the drawings corresponds to the actual layer arrangement.

When selecting the protective measures, the documentation for the first layer of covering above Roof BM must be checked. The model and detail should take into account the fact that the presence of bitumen in the facing does not constitute consent for arbitrary torch work. The set of materials is intended to allow the selection of compatible contact materials and the sequence of works for the actual roof. In the specification, explain the type of adhesive or fixing and the surface preparation conditions, while maintaining the separate functions of the protective layers.

CS150 and class F within the relevant scope

Utherm Roof BM has a declared compressive stress of at least 150 kPa at 10% deformation and reaction-to-fire class F. The compression parameter describes a specific test of the board, and class F describes its reaction to fire. Neither of them determines the fire resistance of the complete roof; this must be assessed for the adopted layer arrangement.

When assessing conformity, the result of the Roof BM test must be separated from the requirements for the complete roof covering. The scope of the documents must not be extended automatically, because the compressive value and the reaction class describe different phenomena and do not prove any arbitrary load-bearing capacity. The design data should allow the loads and the fire protection to be assessed within the appropriate scope. When approving the product, check the product data together with the support and fixing solution and the classification of the system, and conformity with the design.

Insulation with polyurethane: selection and quotation for Roof BM

The order must identify Roof BM by its full designation, thickness and the selected waterproofing, because “PIR board” alone does not indicate the facings or the variant. In the purchasing conditions, state the bonding side and the thickness, and then link them to the material equivalence check: the offer should correspond to the same layer build-up, not just the family name.

In the material procedure, it is worth linking the delivery of Roof BM with the materials needed for a conforming covering. One conforming characteristic does not conclude the analysis, because the same PIR name does not mean interchangeable facings or an identical lambda. The material procedure should allow complete solutions to be compared once the required thermal insulation performance has been established. In the delivery agreement, state the full designation of the board, the description of the contact layers and the scope of work at the details, so that the decision remains reproducible after installation.

A case worth considering

In the Roof BM specification, it is best to state the lambda and R_D separately for each ordered thickness. This avoids assigning the 120 mm parameter to the 100 mm variant. The orientation of the facings and the compatibility of the waterproofing must also be specified. CS150 and the product’s class F are separate pieces of information. The design should combine them with the requirements for the complete roof covering, without replacing them with a general statement about high quality.

7 branches. Materials closer to your project.

Izoprofil.eu map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]

Check prices and availability: +48 500 409 109

Free quote

Materials for your project