Accounting for linear thermal bridges when choosing insulation

EPS and thermal insulation

At a glance

Linear thermal bridges must be assessed together with the thermal insulation of the walls, roof and floor. They occur at junctions where heat flows differently than through the flat field of the building component. They are described by the ψ coefficient and the length of the detail. Thicker EPS in the middle of the wall will not always improve the junction at a balcony, plinth or reveal. A design that ensures continuity of the insulation is needed. A thermal bridge can result from the geometry, a change of material or an interruption of the insulation. Typical locations are the junction of the wall with the ceiling, balcony, roof and foundation. Around them, heat flow is two- or three-dimensional in nature. It cannot always be described by simply adding the resistances of successive flat layers.

EPS board and corner concrete element placed by a spirit level and tape measure

A thermal bridge is not just a gap between boards

Even carefully laid boards do not eliminate every structural thermal bridge.

Gaps between the boards are a separate installation issue and also require improvement. However, all losses should not be reduced to the quality of the EPS joints. A concrete element passing through the thermal insulation can remain significant despite very careful installation. That is why the assessment starts from the detail drawing of the junction, and not from the list of material lambdas alone.

What does the ψ coefficient mean?

The ψ coefficient, given in W/(m·K), describes the additional effect of a linear junction relative to the adopted model of component fields. To obtain the balance component in W/K, it is multiplied by the length of the detail. It is not the lambda of a material. Its value depends on the geometry, the layer arrangement and the rules for dimension reference. One number should not be attributed to every balcony or plinth.

Catalogue data can be useful if they correspond to the actual solution. The wall material, thicknesses, position of the insulation and the method of dimensioning must be compared. Where there are significant differences, an appropriate calculation is needed. Copying a low ψ value from a similar illustration can underestimate the losses. The documentation should make clear which detail and which assumptions the result describes.

How significant can the length of a junction be?

Let us assume, by convention, 100 m² of wall with U = 0.20 W/(m²·K). The component from its area is 20 W/K. For a junction 30 m long with ψ = 0.10 W/(m·K), 3 W/K are added. At a temperature difference of 20 K, this detail corresponds to an additional 60 W. This is an example calculation, not a typical value for any house.

If ψ for the same junction can be reduced to 0.03, its component will be 0.9 W/K. This is a reduction of 2.1 W/K. It is worth comparing such an effect with the effect of additional centimetres of EPS in the wall field. The comparison should cover the cost and feasibility of both changes. A long, moderately weak detail can matter more than a short section with a worse coefficient.

Also monitor the surface temperature

A thermal bridge affects not only the amount of heat but also the local temperature on the interior side. A cooler area can matter for the risk of condensation and mould growth at a given humidity. The total heat loss of the whole building alone does not show this issue. That is why the analysis of a detail should also include the minimum surface temperature and the appropriate humidity criteria.

There is no single safe temperature for every room. The assessment depends on the air conditions and the method adopted. High humidity can worsen the situation even after the insulation has been improved. Conversely, correct ventilation is not a justification for leaving a defective detail. Thermal insulation and conditions of use should be treated as elements that work together, not as mutual substitutes.

How can the continuity of EPS be improved in practice?

First, the insulation of adjacent building components must be brought up to the designed junction. This applies to the junction of the façade with the roof, the plinth and the floor. At window reveals, the position where the window is installed and the insulation at the frame are important. Increasing the thickness on a large flat surface alone may leave these places unchanged. The drawings should also indicate the sequence of works and the access needed to make the junctions.

Some structural thermal bridges require a solution other than adding EPS on top. In that case, the load-bearing capacity and the fixing conditions must be taken into account. The concrete element must not be cut on site, nor the support replaced with insulation. The designer should assess the possible options. Likewise, the local use of a thinner material requires verification that it retains the necessary mechanical and system properties.

How can the calculations and acceptance be organised?

In the schedule, it is worth separating envelope areas, linear junctions and point thermal bridges. The same dimensioning conventions must be retained and double counting avoided. If Uc already includes specific fixings, they are not added a second time. The result should be reproducible from the drawings, areas, lengths and the data specified. This is important also for later substitution of materials.

EPS is produced by, among others, Austrotherm, Arsanit, Paneltech and Enerpor. The selection of their specific boards should follow from the junction design and the requirements of the entire envelope. On site, it is worth documenting the edges before they are covered. Even the best lambda value will not help in a place where the insulation is missing or was terminated earlier than the verified detail assumed.

7 branches. Materials closer to your project.

Izoprofil.eu map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]

Check prices and availability: +48 500 409 109

Free quote

Materials for your project