Designing with Utherm Sarking LE Plus: edges, membrane and details

PIR insulation

At a glance

The description of Utherm Sarking LE Plus should separate the product data from the calculation of the counter-batten fixing. The large format and the edge profile do not determine the screw spacing. The project also needs membrane details so that the scope of supply matches the intended execution. Utherm Sarking LE Plus belongs to the PIR boards for pitched roofs. On both sides it has a multi-layer gas-tight laminate. The terms “polyurethane boards” and “polyurethane foam” are broader than the precise designation of the PIR product. In the description of use for PIR boards, the difference between Utherm Sarking LE and the LE Plus variant with the additional membrane must be stated unambiguously. The description of function should make it possible to establish the full name of the Sarking variant before additional membranes are selected.

Utherm Sarking LE Plus – board and facing construction

Sarking LE PIR boards and the additional Plus membrane

A shortened material item is not sufficient, because the standard LE variant cannot be assigned the factory-made element characteristic of Plus. The functional criteria are intended to allow the actual extent of the sarking layer to be determined before purchase. In the documentation, enter the name of the variant and a list of separate materials for laps and terminations, and clearly indicate the place of application.

Resistance of the layer above the timber structure

For the thermal calculations of the roof assembly, adopt a lambda of 0.022 W/(m·K) as given in the UNILIN catalogue for Sarking LE Plus. The layer of PIR boards laid above the rafters reduces the share of timber in the heat flow path through the main thermal insulation, so in the calculation schedule describe it as a continuous Sarking LE Plus layer with this lambda above the timber. A system recorded in this way allows the effect of the low thermal conductivity to be separated from the improvement in the continuity of the roof slope and remains consistent with the cross-section of the structure.

The calculations must take into account the rafters and the fasteners passing through the Sarking LE Plus layer. The data must remain within their scope, since the above-rafter layer limits the influence of the timber but does not eliminate all thermal bridges. Verification of the solution should allow the benefit of the low thickness to be separated from the improvement in the continuity of the entire roof slope. Retain the cross-section of the structure together with the assessment of the roof-to-wall junction, so that a later replacement can be checked against the same assumptions.

Polyurethane insulation made from large profiled boards

In the construction design, indicate the Sarking LE Plus format of 2400 × 1200 mm and the tongue and groove on all four sides. The edge profile makes it easier to fit adjacent boards, but it does not replace the fixing or sealing of the sarking layer, so describe the screw spacing and the method of anchoring separately, on the basis of the structural data and the actions on the roof. On the drawing, show the position of the factory edges, supports and cut lines, so that cutting to size does not remove the profile without an adopted termination solution.

The construction drawing should help fit the large Sarking LE Plus boards to the roof valley, eaves and openings. It is not worth leaving this until the crew is on site, given that cutting to size may remove the profile and require a different termination solution. The adopted geometry should allow the layout of the elements to be planned before the material is carried onto the sloping surface. For acceptance of the polyurethane insulation, define the position of the factory edges, supports and cut lines in difficult locations. Also establish the inspection to be carried out before covering.

Membrane laps and terminations at openings

The Plus membrane factory-bonded to the board simplifies the layer build-up, but does not automatically close the perimeter of every opening. In the analysis of the partition’s conditions, include the overlap of the Plus membrane at the roof window and at the base of an element penetrating the roof slope, and in the specification describe the sealing of openings after fixings, of junctions at the wall and of service penetrations. Indicate the accessories, the run of the overlaps and the sequence for closing the layers, while preserving the separate functions of the protective layers.

When selecting the protective measures, the direction of water runoff and access to the sealing of the Plus membrane must be preserved. The model and detail should take into account the fact that the membrane on the full board does not automatically close the perimeter of every opening. The material set should allow the factory part to be combined with details made on site. In the specification, explain the run of the overlaps, the accessories at penetrations and the sequence for closing the layers, while preserving the separate functions of the protective layers.

Requirements at the chimney and attic comfort

In the fire documentation, Utherm Sarking LE Plus must not be described as a non-combustible material – the declared reaction to fire class for this variant is E. The board alone does not exempt you from maintaining the required distances and protective measures in the vicinity of the chimney, which is why two issues must be separated in the design: the conditions at the hot element and the limitation of solar gains in a loft insulated with this variant. Both entries should go into the specification as separate performance requirements, linked to the chimney detail drawing and to the assumptions concerning the partitions.

When assessing conformity, fire protection and summer conditions in the attic must be considered separately. The scope of the documents cannot be extended automatically, because reaction class E does not mean non-combustibility, and a low lambda does not guarantee a single temperature in summer. The design data should make it possible to retain the correct solution at the hot component and to assess the actual heat sources. When approving the product, check the chimney detail and the assumptions regarding windows, blinds and air exchange, and conformity with the design.

Insulation with polyurethane above the rafters: the full scope

In the request for quotation and in the bill of materials, list Sarking LE and Sarking LE Plus as separate items, because they are different variants, not interchangeable descriptions of the same board. For each item, give the thickness, the coverage area and the supplementary components, and also indicate how the membrane is to be protected in transport. The purchasing conditions should also explain the change in covering height resulting from adding Sarking LE Plus above the rafters, so that the order corresponds to the adopted layer arrangement.

In the materials procedure, it is worth pricing the fixings, flashings and work at the gutter alongside Sarking LE Plus itself. One conforming characteristic does not conclude the analysis, because the behaviour of the interior location may involve matching components on the outside of the roof. The materials procedure should make it possible to compare complete renovation scopes with an identical attic function. In the delivery agreement, indicate the layer balance and the list of works at the eaves, windows, ridge and penetrations, so that the decision remains reproducible after installation.

A case worth considering

In the design, the properties of the Sarking LE Plus board must be separated from the solution for fixing the counter-battens. The 2400 × 1200 mm format does not specify the screw spacing or their anchorage. Data on the structure and the actions on the roof are needed. It is also worth specifying how the membrane is terminated at openings. An arrangement recorded in this way can be checked on site without having to guess the missing components.

7 branches. Materials closer to your project.

Izoprofil.eu map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]

Check prices and availability: +48 500 409 109

Free quote

Materials for your project