BauderPIR FA: coverage dimensions and construction specification data
PIR insulation
For FA, a distinction must be made between the external dimension and the installation dimension. The first helps to describe the board, the second is used for planning the coverage. The specification should state which basis was used for the material quantity. This avoids an apparent conformity of the quotation that states the correct format but too small a number of boards. The BauderPIR FA specification should identify the function that the thermal insulation of a large, regular roof area is to perform. An element requiring an unambiguous description is the milled edge of the large-format board. The input data should include the area of actual coverage and the widths of the perimeter strips, not only the area intended for thermal insulation. The coordinating document remains the row plan based on the effective dimension of the boards.

In this article
Input data for the specification
It must be recorded who confirms that the task can be carried out: covering the roof slope while correctly allowing for laps and cut-offs. In this respect, the person responsible should be the coordinator for measurement and roof-slope organisation, in accordance with the division of design work.
The correct product and the scope of its data
In the construction documentation, BauderPIR FA is described as a board with a PIR core and aluminium facings on both sides, with external dimensions of 2400 × 1200 mm and coverage dimensions of 2385 × 1185 mm, with a rebate forming a 15 mm wide lap. The product description includes: declared λD 0.022 W/(m·K), compression level CS(10/Y)120 and reaction to fire E. With such a large format, the board is not assigned the role of a self-supporting structural element. The example considered in this guide is the thermal insulation of a large, regular roof field. The PIR core and facings are considered together as the properties of the complete board, and the term insulation itself here refers to the installation of factory-made boards in a defined layer build-up.
What the presented calculation covers
Draw the BauderPIR FA rows according to the installation dimension, allowing for the 15 mm wide rebate. In the thermal part, an example can be shown for 100 mm and a lambda of 0.022 W/(m·K): 0.10/λ is approximately 4.55 m²K/W. The calculation illustrates the relationship between thickness and conductivity, but does not replace the RD declared according to the manufacturer’s documentation. On acceptance of the delivery, check the FA marking and the edge geometry, which determine whether the laying plan can be reproduced.
For BauderPIR FA, the distinction between the product data and the result of the overall solution must be maintained. The analysis uses the characteristic: coverage dimension 2385 × 1185 mm. The assessment must take into account the limitation: loss of coverage area resulting from the lap. Before approving the variant, the external dimension must be compared with the installation dimension before measurement and the result recorded in the documentation. Reproducing the assumptions is made possible by a row plan based on the effective board dimension. This ensures that a later comparison with another offer does not omit the element described as the rebated edge of the large-format board.
Conditions for assessing the variant
In the project, the behaviour described as laying out full boards in regular rows can be compared with the solution of adapting the layout to zones with numerous cuts. The criterion should follow from the need to cover the roof slope while correctly accounting for laps and offcuts. For BauderPIR FA, retaining a single figure from the data sheet does not mean that the entire cross-section is equivalent. The requirements must also take into account the groove that forms a 15 mm wide lap. Ordering material according to the 2400 × 1200 mm outline without allowing for the groove must be ruled out, because it changes the meaning of the recorded parameter. The decision should be presented by the coordinator for measurement and roof slope organisation, together with the scope of changes for adjacent materials. The adopted variant must be linked to the schedule: the list of coverage areas and the pallet layout plan.
Description of the execution of the relevant joint
The drawing should unambiguously indicate the grooved edge of the large-format board. In the case of BauderPIR FA, the surface of the material formed by the double-sided aluminium facing BauderPIR FA must also be described. The preparation must provide the support intended for large roof sheets. The required inspection point occurs before the stage described as covering matched to the BauderPIR FA layout. The basis for acceptance is the record of the FA designation and confirmation of the 15 mm groove, assigned to the drawing and the place of execution. Such a description limits discretionary decisions by the crew at a point that will not be visible later.
Delivery and acceptance documents
The delivery of BauderPIR FA should be assignable to a single specification item. This item is expanded by the list of coverage areas and the pallet layout plan; every described feature should have a reference to the project. A record of the FA designation and confirmation of the 15 mm groove is needed, allowing the variant and the manner of its use to be confirmed. If conditions change, the loss of coverage area resulting from the lap must be reconsidered. The update should be agreed by the coordinator for measurement and roof slope organisation before the next layer conceals the discrepancy. The polyurethane insulation is thus linked to the executed scope, namely the thermal insulation of a large, regular roof field.
A record that can be verified later
The final description of BauderPIR FA should allow the adopted decision to be reproduced without guessing its purpose. In this case, the purpose can be defined as the need to cover the roof slope while correctly accounting for laps and offcuts. The description should be accompanied by a row plan based on the effective board dimension. The grooved edge of the large-format board should be indicated separately where its solution differs from the main field. The record should cover the entire required scope. When proposing a substitute, the external dimension must be compared again with the installation dimension before measurement, instead of basing the assessment solely on the name PIR. Polyurethane boards are then compared according to verifiable features and the effects on the specific cross-section.